Call Us

+8615579917678

E-mail Us

texus@texusair.com

Double-stage compression permanent magnet variable frequency screw compressor KBseries

315kw two-stage compression screw air compressor

1.two-stage integrated main machine
 The two-stage compression main engine is adopted, that is, the first-stage compression rotor and the second-stage compression rotor are combined in one housing, and are directly driven by helical gears. Natural air enters the first-stage compression through the air filter, mixes with a small amount of lubricating oil in the compression chamber, and compresses the mixed gas to the interstage pressure. The compressed gas enters the cooling channel and contacts with a large amount of oil mist, which greatly reduces the temperature. The compressed gas after cooling enters the second-stage rotor for secondary compression and is compressed to the final exhaust pressure.


2. PM electric motor
The motor uses the magnetic field generated by the AC voltage related to the stator coil and the magnetic force of the magnetic field to make the rotor rotate. The permanent magnet synchronous motor uses high-performance NdFeB permanent magnets, which do not lose magnetism at 120°C. It uses high-quality elastic couplings for direct transmission. The permanent magnet motor is integrated with the compressor host, which has a more compact structure, higher transmission accuracy and efficiency.


3.centrifugal fans VF control system

The centrifugal fan adopts variable frequency control, which can save energy by about 50%. According to the exhaust temperature, the fan speed is controlled to control power waste. At the same time, the noise is further reduced because the system and the overall component temperature are stabilized; because of the variable frequency control of the fan, the noise is further reduced.

Centrifugal fans have advantages such as high efficiency, no wind blind area, and stable pressure curve.

Product Details
Technical Parmeters
Catalogue Download

http://www.texusair.com/Double-stage-compression-permanent-magnet-variable-frequency-screw-compressor-KBseries/double-stage-compression-permanent-magne.htmlDouble-Stage Screw Compressor Product Features


01- Energy saving motor

Fully enclosed permanent magnet motor, with high overload capacity, high efficiency, high power factor.


02- Efficient double-stage screw compressor  host

Primary energy efficiency double-stage screw compressor main engine; Low speed, low noise, high displacement, durable stability and reliability.


03- Intelligent control system

Control at your fingertips, ease of use, more information, more accurate and fast fault diagnosis.

National level two energy efficiency compression, a new internal layout


Advantages of Texusa Brand


Innovating technology and protecting the environment, Texusa listens, understands and meets customer needs.

Save the environment, ensure better services and solutions, save costs for users, and seek maximum growth space. The main purpose is to protect and save energy, stimulate the growth of economic productivity, comply with market demand, save energy and reduce environmental pollution.

With the mission of "innovation reflects value", texus company will continue to promote technological innovation and progress, achieve win-win results with global partners, suppliers, and employees, and create a new world of "energy saving, environmental protection, intelligence, and service". Committed to the field of aerodynamics and striving to become a world-class enterprise with world-class standards.



Permanent Magnet Screw Compressor Working Schematics


Double-stage compression permanent magnet variable frequency screw compressor


Advantages


1. High quality control(CE,SGS,ISO14001/Energy saving certificate)

2. Fast Delivery( 25-30 days for large orders)

3. Good service for pre-sale,after-sale( strong technical support and professional after-sales team)

4. Small order acceptable( Ordering quantity according to your actual needs)


Why Choose Us


Low noise

Normal operation 67db, low operating noise makes it suitable for a wider range of occasions


Save 33-40% of electricity

- A 75KW ordinary air compressor runs 8,000 hours a year, and the electricity bill is about 372,000 yuan. The Texus air compressor saves 35% energy per year (372,000 yuan*35%=130,200 yuan).

315kw two-stage compression screw air compressor


Double stage compression variable frequency screw air compressor

ModelNominal
Power
Working
Pressure
Free Air
Delivery
Weight(KG)Noise
Level
50HzKW HPbarpsim3/mincfmKGdb(A)
KB18.5-818.52581163.5123.60 63068
KB22-8223081164.2148.32 66068
KB30-8304081166.0 211.89 92068
KB37-8375081167.0 247.20 95068
KB45-8456081169.5335.49 153074
KB55-85575811612.0 423.78 158074
KB75-875100811615.0 529.72 162074
KB90-890125811618.0 635.66 210074
KB110-8110150811622.5794.58 290078
KB132-8132175811625.5900.52 305078
KB160-8160200811629.80 1052.38 385082
KB185-8185250811637.00 1306.64 400082
KB200-8200275811640.50 1430.24 530084
KB220-8220300811643.00 1518.53 570084
KB250-8250350811648.50 1712.76 630085
KB280-8280375811653.00 1871.68 700085
KB315-8315420811659.50 2101.22 780088
KB355-83554808116702472.03 865088
KB400-84005458116a#VALUE!925088
KB450-84506108116933284.26 950088


AIR COMPRESSOR MAINTENANCE

01

The air compressor shouldbe placed in a place withclean air and good ventilation.

The air compressor shouldbe placed in a place withclean air and good ventilation.

02

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

03

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

04

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

ENERGY SAVING THCHNOLOGY

Power saving of 17000o kWh per month

The starting power of the original system is 555kw,and the starting power of the new system is 320kw.

Power saving of 17000o kWh per month

Power saving of 54000 kWh per month

The starting power of the original system is 240kW,and the starting power of the new system is 132kw.

Power saving of 54000 kWh per month

Power saving of 86000 kWh per month

The starting power of the original system is 446kW,and the starting power of the new system is 325kW.

Power saving of 86000 kWh per month

Power saving of 260000 kWh per month

The starting power of the original system is 690kw,and the starting power of the new system is 420kw.

Power saving of 260000 kWh per month

Power saving of 167000 kWh per month

The starting power of the original system is 732kW,and the starting power of the new system is 50okw.

Power saving of 167000 kWh per month

Power saving of 79000 kWh per month

The starting power of the original system is 430kw,and the starting power of the new system is 320kw.

Power saving of 79000 kWh per month

Copyright © Texus Air Compressor Co., Ltd. All Rights Reserved | Sitemap | Technical Support: Reanod