85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX

Model : TP-15-D
Air Capacity : 85CFM
Electrical : 1 Phase
Interface size :1”
Working Operating pressure : 102-145 PSI
Cooling : By Air
Ambient temperature :  0-95℉   
Intake air temperature :  ≤113℉  
Power supply : 110V/60Hz 
Refrigerant type : R134a 
Installed power : 550W 
Dimension : 30 *17 *32 Inch
Weight : 86 lb
Warranty : 1 Year


Product Details
Technical Parmeters
Catalogue Download
85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX
 
Model : TP-15-D
Air Capacity : 85CFM
Electrical : 1 Phase
Interface size :1”
Working Operating pressure : 102-145 PSI
Cooling : By Air
Ambient temperature :  0-95℉   
Intake air temperature :  ≤113℉  
Power supply : 110V/60Hz 
Refrigerant type : R134a 
Installed power : 550W 
Dimension : 30 *17 *32 Inch
Weight : 86 lb
Warranty : 1 Year

85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX

85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX

85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX

85 CFM REFRIGERATED COMPRESSED AIR DRYER 110V/60HZ, FOR 20HP COMPRESSORS MAX






AIR COMPRESSOR MAINTENANCE

01

The air compressor shouldbe placed in a place withclean air and good ventilation.

The air compressor shouldbe placed in a place withclean air and good ventilation.

02

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

The air compressor should be placedhorizontally, with the belt side facingthe wall, and the maintenancespaceshould be reserved.

03

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

Before repairing and disassemblingthe air compressor, please tum offthe power supply and dischargethe air in the air seam.

04

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

When wiring, check whether thefan rotation direction is consistentwith the arrow direction.

ENERGY SAVING THCHNOLOGY

Power saving of 17000o kWh per month

The starting power of the original system is 555kw,and the starting power of the new system is 320kw.

Power saving of 17000o kWh per month

Power saving of 54000 kWh per month

The starting power of the original system is 240kW,and the starting power of the new system is 132kw.

Power saving of 54000 kWh per month

Power saving of 86000 kWh per month

The starting power of the original system is 446kW,and the starting power of the new system is 325kW.

Power saving of 86000 kWh per month

Power saving of 260000 kWh per month

The starting power of the original system is 690kw,and the starting power of the new system is 420kw.

Power saving of 260000 kWh per month

Power saving of 167000 kWh per month

The starting power of the original system is 732kW,and the starting power of the new system is 50okw.

Power saving of 167000 kWh per month

Power saving of 79000 kWh per month

The starting power of the original system is 430kw,and the starting power of the new system is 320kw.

Power saving of 79000 kWh per month

Copyright © LRSD Air Compressor Co., Ltd. All Rights Reserved | Sitemap